onsale
-
Prezzo 4,00 € 4,50 € -14%
NEUTRIK NC3FXX
Prezzo 4,30 € 4,90 € -13%XLR volante, Serie XX, 3 poli femmina, corpo nichel, contatti argento
NEUTRIK NE8FDV-YK-B
Prezzo 12,30 € 13,30 € -7%EtherCON Serie D, a pannello, CAT5 femmina, corpo nichel, IDC punch down
NEUTRIK NC3MXX-B
Prezzo 4,30 € 4,90 € -13%XLR volante, Serie XX, 3 poli maschio, corpo nero, contatti oro
Offerta del giorno
Featured Products
A compact DIN and easy to deploy Ethernet/DMX processing device that fits every fixed installation.
DIN rail mountable for fixed install
LumiNode 4 DIN is specifically designed for fixed installations to fit on a standard DIN rail. The compact design and standardised mounting bracket is ideal for Architainment applications and install projects. For full flexibility the unit comes either with DMX/RDM RJ45 connectors or Terminal Blocks.
The unit can be powered over PoE or DC voltage. The second 1Gb RJ45 Ethernet port can be used to connect any other application or the next LumiNode 4 DIN (DC powered).
Each DMX/RDM port is fully optically and galvanically isolated and can be configured as an in- or output. All relevant industry standard protocols such as Art-Net, sACN, KiNET, RTTRpl (Blacktrax) are supported and can be processed and converted by the 6 onboard process engines supporting HTP, LTP, Crossfade, Backup, Switch and Custom merging modes with soft patch functionality.
Industry protocols
All relevant industry-standard protocols such as Art-Net, sACN, KiNET, RTTrPL (Blacktrax) are supported.
The LumiNode family is fully DMX/RDM compatible. LumiNet Monitor and other third party RDM software or lighting consoles (supporting ArtNet RDM) can make use of the full RDM functionality.
Intuitive UI
The built-in web UI delivers a great user experience.
Process engines can be easily configured in a very intuitive workflow. Just decide what you like to do with your lighting data by choosing the mode of the process engine.
Depending on the chosen merging/routing policy of the engine, the UI presents all possible input configurations. From here you just connect your input streams and your output connections.
Everything can be easily stored and recalled into profiles for later usage.
Advanced networking
Use the full capacity of the Gigabit connectivity by sending different data in a different Group (VLAN). Setup a separate interface for IT monitoring without interfering with critical lighting data.
The known Group (VLAN) technology from GigaCore switches is also available in the LumiNode product family. This allows you to freely assign a different Group (VLAN) to the different network connectors and to the node's interfaces.
ISL (Inter Switch Link) and custom trunks are available to transfer different VLANs on one ethernet connection.
Play & contact closure
Play allows you to record snapshots of all your output streams in a show as queue list with fade times. This show can later be used as an input source of a process engine.
The external contact closure can be configured as a trigger on the network and be used as any other trigger source to control the playback of the recorded queue list.
Integration with web API
LumiNode features a fully documented web API, making the unit ideal for integration and automation in installation projects.
All configuration or manipulation (like recalling profiles, configuring engines, triggering play,...) can be done via web API (REST/JSON). Offering the maximum flexibility to integrate with any other hardware or software to control your infrastructure.
Connectivity
- DMX/RDM connectivity:
- 4 x RJ45-DMX (ANSI E1.11 – 2008 (R2018))
- 4x 3-pin pluggable terminal block
- Ethernet connectivity: 2 x gigabit RJ45
- Contact closure: Yes
- Power connectivity:
- 1x 3-pin pluggable terminal block
- Ethernet (PoE 802.3af class 0)
- DMX features
DMX protocols:
- DMX512 (1986 & 1990)
- DMX512-A ANSI E1.11
- RDM ANSI E1.20-2010
- DMX port direction: Input or output (configurable)
- DMX port isolation: Optical and galvanic isolation per port
- DMX timing:
- Framerate: 10-40fps
- Break: 176-352µs
- Network features
Ethernet protocols:
- Art-Net™ (1-4)
- sACN ANSI E1.31
- RTTrPL (BlackTraX)
- KiNET v1, v2
- Ethernet port speed: 10/100/1000Mbps
Port sensing:
- Auto-negociation
- MDI / MDIX
- Split management interface: Yes
- Groups (VLAN) support: Yes
- Key features
- Process engines: 6
Merging engine:
- HTP
- LTP
- Backup
- Switch
- X-Fade
- Custom
- Softpatch: Yes
Master/Limit:
- Proportional
- Limit
- Trigger system: Yes
- ReRoute: Yes
- Profile manager: Yes
- Snapshot: Yes
- DMX Redundancy: Yes
- Monitoring software: LumiNet Monitor, Araneo
Configuration:
- Built in Web server
- Documented Web API
- Status
- Display and jog: No
- Status LEDs:
- Ethernet Port: link/activity LED and Group RGB LED
- DMX Port: DMX/RDM LED
- Power ok
Power
- Power input:
- 12-24 VDC
- PoE IEEE 802.3af (Class 0)
- Power consumption: Maximum 10W
- Power redundancy: Yes
- Environmental
- Operating temperature: -10 to +60°C
- Storage temperature: -10 tot +70°C
- Humidity (non condensing): 5 to 95% RH
Physical
- Enclosure: Robust plastic housing
- Mounting: Din Rail IEC/EN 60715 mount
- Dimensions (W x D x H): 156,30 x 86 x 35,8 mm
- Weight: 0.,27 kg
- Packaging: 305 x 215 x 110 mm
Approvals
- Electromagnetic emissions and immunity:
- EN55032 class A
- EN55035
- EN61000-3-2
- EN61000-3-3
- EN61000-4-2
- EN61000-4-4
- EN61000-4-5
- EN61000-4-6
- EN61000-4-8
- EN61000-4-11
- FCC Part 15 CFR 47 class A
- ICES-003 Issue 6
- Safety:
- IEC 62368-1
- EN 62368-1
- UL 62368-1
- CAN/CSA-C22.2 No. 62368-1
- CE
Certificates:
- cSGSus Mark
- CE
- UKCA
- CB certificate
- Green:
- RoHS
- REACH
Riferimenti Specifici
16 prodotti nella stessa categoria:
On sale
-
K&M 26250 Asta microfonica »Performance« - nera
Prezzo 83,00 € 124,00 € -33%Asta microfonica »Performance«
K&M 26085 Asta microfonica dritta con frizione "One Hand" - nera
Prezzo 48,00 € 67,00 € -28%Asta microfonica dritta con frizione "One Hand"
K&M 25993 Supporto per microfono
Prezzo 52,00 € 73,00 € -29%Supporto per microfono salvaspazio per grancassa, AMP, Cajons, ecc
bestseller