Rupert Neve Designs Portico 543 500 Series
  • -9%

Rupert Neve Designs Portico 543


€1,188.00
€1,086.00 -9%
Tax included
Lowest price within the last 30 days: €1,086.00

500 Series Compressor


Qty

Available

Do you want to receive it on: Wednesday, 08/01/2025? Order within 1 hours and 6 minutes

Free shipping

GFP

We will plant 1 tree and protect part of a tropical rainforest for every order placed on our website.

See our impact in real-time

wishlist

Rupert Neve Designs Portico 543

 

Clean, precise, powerful level control.

Whether you’re tracking, mixing or mastering, the 543 delivers unobtrusive, musical dynamic control and high-ratio limiting with massive flexibility, transparency and precision.

The 543 features a fully controllable compressor-limiter with feed-forward / feedback modes, Peak / RMS detection and a built-in side chain high pass filter. With an unrivaled heritage and a tremendous feature set, the 543 provides an astonishing degree of flexibility and precision.

What is VCA compression?

Every compressor has a gain control element in its circuit, and this is generally what determines the “sound” of the compressor. Some compressors use tubes, some use FETs, some use light-dependent resistors, some use a diode bridge – but in the 543, a VCA (Voltage Controlled Amplifier / Attenuator) is used to control the signal’s gain. 

In contrast to a diode bridge design like our 535 compressor, which adds a thick, very colorful tonality to the source, the 543 makes use of a very accurate, low noise, low distortion VCA. This provides an immense amount of dynamic control and subtle warmth, without necessarily leaving a heavy sonic imprint on your tracks or mixes.

Feed-Forward or Feed-Back?

This switch changes the point in the signal path where the VCA control voltage is picked off: either before the VCA (feed-forward) or after the VCA (feed-back). 

In most of Mr. Neve’s earliest designs, feed-back detection was intrinsic to the musical dynamic response. However, the very nature of a feedback compressor limits the attack time of the compression circuit, as the control voltage has already passed through the VCA itself. To offer faster, more technically accurate response times, feed-forward detection was also implemented in the 543: with the FF / FB switch, both classic and modern VCA responses are available.

RMS or Peak?

Another highly useful features of the 543 is the Peak / RMS mode, which allows the VCA to respond to both RMS (Root Mean Square) and peak levels. RMS circuits are considered to better mimic the way the ears perceive apparent loudness, while peak circuits tend to directly respond to the waveform voltage, which may be more of a concern for prevention of clipping and maximizing levels. 

In the case of this particular circuit, peak mode actually uses a combination of both methods to get the best of both worlds, and avoids the drawbacks of each method on its own.

THRESHOLD

Sets level where the compressor may begin to react from -30 dB to +20 dB. Minimal or no compression is with this control fully clockwise and it gets more sensitive and tends to cause more gain reduction as the knob is rotated counter-clockwise (which may be counter-intuitive to some). 

RATIO

Sets the “slope” of the compression from 1.1:1 (minimal) to 40:1 (Limit) . For example, if set for 3:1 and the input signal rises by 3dB, the output signal will only rise by 1dB. In general, low ratios can not damage the music as much as high ratios but high ratios may be more useful to minimize clipping and OL lights in the recorder.

COMP IN 

Engages the compressor section of the unit.

F/F + F/B 

These are two very different compressor modes, FEED FORWARD and FEED BACK. The F/B mode (button in) tends to sound smoother and often more natural and tends to be quicker to set up. The F/F mode can be more useful for shaping the envelope of the sound and introducing more bounce and pumping in time with the song, when that is the goal.

GAIN 

Continuously variable from -6 dB to +20 dB. 

ATTACK

This sets how quickly the compressor reacts and starts attenuating. Continuously variable from 20mS to 75mS.

RELEASE

This sets how fast the compressor returns back to zero after attenuating. Typically engineers use slower release times when the intention is to minimize any obvious compressor action or gains changing. Continuously variable from 100mS to 2.5 Seconds.

RMS/PEAK

This changes the compressor from essentially responding to the RMS level of the audio to also responding to the PEAK level. RMS (root mean squared) circuits are considered to better mimic the way the ears perceive apparent loudness, while Peak circuits tend to directly respond to the waveform voltage which may be more of a concern for prevention of clipping and maximizing levels.

SIDECHAIN HPF

This routes a high pass filter set to 250 Hz into the circuit that the compressor uses to determine level. Note that the rest of the circuit and output will not have those lows filtered out – this only determines the portion of the signal that is affected by the compressor. This is very useful when you want your low frequency content to come through unaffected while still compressing the mids and highs.

LINK

When link buss is provided by the 500 series rack, this can be used to link the reduction of two 543 units together.

GAIN RANGE

  • Continuously variable from -6 dB to +20 dB

THRESHOLD RANGE

  • Continuously variable from -30 dB to +20 dB

RATIO RANGE

  • Continuously variable from 1.1:1 to Limit (40:1)

ATTACK RANGE

  • Continuously variable from 20mS to 75mS

RELEASE RANGE

  • Continuously variable from 100mS to 2.5 Seconds

TOTAL HARMONIC DISTORTION AND NOISE

  •  1 kHz, 0 dBu output level, no load.
  • Main Output, compressor bypassed: Better than 0.002%
  •  20 dBu better than 0.0015%
  • Main output, compressor engaged: Better than 0.075%

NOISE

  • Measured at Main Output, un-weighted, 22 Hz - 22 kHz, Terminated 50 Ohm.
  • With Gain at Unity, Compressor disengaged: Better than -98 dBu
  • With Gain at Unity, Compressor engaged: Better than -93 dBu

FREQUENCY RESPONSE

  • Main Output, Unity Gain:  150 kHz -3 dB

METERS

  • Monitors INPUT LEVEL and GAIN REDUCTION

LINE INPUT IMPEDANCE

  • 10,000 Ohms

MAXIMUM OUTPUT LEVEL

  • 21 dBu from 20 Hz to 40 kHz

POWER REQUIREMENTS

  • 500 series rack with 110-125 mA @ +/- 16V